四方鐵工作角偏差的測(cè)量不確定度分析
打開(kāi)文本圖片集
【摘要】本文通過(guò)對(duì)四方鐵工作角的偏差測(cè)量結(jié)果的不確定度進(jìn)行概算,根據(jù)JJF 1130—2005《幾何量測(cè)量設(shè)備校準(zhǔn)中的不確定度評(píng)定指南》中目標(biāo)不確定度合格判據(jù)U≤UT,確認(rèn)本文提出的四方鐵工作角的偏差的技術(shù)要求、測(cè)量原理、測(cè)量條件、測(cè)量方法和測(cè)量程序的科學(xué)性、經(jīng)濟(jì)性及可行性。
【關(guān)鍵詞】光學(xué)儀器檢具;四方鐵;不確定度
【DOI編碼】10.3969/j.issn.1674-4977.2023.02.016
Analysis of the Measurement Uncertainty of the Deviation of the Working Angle of Tetragonal Iron
LI Fan1,WANG Muhan2
(1.Liaoning Institute of Measurement,Shenyang 110004,China;2.Fushun Institute of Technology Innovation,F(xiàn)ushun 113006,China)
Abstract:This paper confirms the scientific,economical and feasible technical requirements,measurement principles,measurement conditions,measurement methods and measurement procedures of the square iron working angle deviation proposed in this paper by estimating the uncertainty of the measurement results of the square iron working angle deviation and according to the objective uncertainty qualification criterion U≤UT in JJF 1130—2005 Guidr to the Estimation of Uncertainty in Calibration of Geometrical Measuring Equipment.
Key words:optical instrument fixture;the quartet iron;uncertainty
1概述
標(biāo)準(zhǔn)角尺有200 mm×100 mm、100 mm×63 mm和70 mm×70 mm等規(guī)格。(剩余2457字)