[摘要]通過從增加兩臺機組重要輔機冗余保護測點,優(yōu)化重要輔機單點保護控制邏輯;獨立開列采用同一根電纜的多個主保護測點及信號電纜;重新分配在同一塊卡件、同一個支線的保護測點等措施,2021年中煤哈密發(fā)電有限公司主輔機設備熱工保護可靠性得到持續(xù)提升,為機組的安全穩(wěn)定運行保駕護航。
[關鍵詞]保護;可靠性;優(yōu)化;冗余;單點保護
[中圖分類號]TM621.7[文獻標志碼]A[文章編號]1001-523X (2022)08-0100-03
Reliability Improvement of "Single Point Protection" of Main and Auxiliary Equipment in Thermal Power Plants
Zhang Guo-kun,Dong Li-jiang
[Abstract]By adding redundant protection measuring points of important auxiliary machines of two units,the singlepoint protection control logic of important auxiliary machines is optimized;multiple main protection measuring points and signal cables using the same cable are listed independently;In 2021,the reliability of thermal protection of the main and auxiliary equipment of China Coal Hami Power Generation Co.,Ltd. will be continuously improved,escorting the safe and stable operation of the unit.