工作用輻射溫度計(jì)固有誤差不確定度評定
打開文本圖片集
【摘要】現(xiàn)行的JJG 856—2015《工作用輻射溫度計(jì)》檢定規(guī)程規(guī)定了可以采用具有亮度溫度校準(zhǔn)結(jié)果的參考黑體輻射源作為標(biāo)準(zhǔn)檢定工作用輻射溫度計(jì)。這種方法操作簡單、便利,常用于日常工作中,但對于不確定度的評定,該規(guī)程并沒有給出范例。本文給出了檢定工作用輻射溫度計(jì)的不確定度評定方法。
【關(guān)鍵詞】參考輻射源;輻射溫度計(jì);溯源;不確定度
【DOI編碼】10.3969/j.issn.1674-4977.2024.06.084
Evaluation of Uncertainty of Intrinsic Error of Radiation Thermometer for Working Purpose
DU Guosheng
(Fushun Inspection, Testing and Certification Center, Fushun 113006, China)
Abstract: The current JJG 856—2015 Radiation Thermometers verification regulation specifies that a reference blackbody radiation source with a calibrated brightness temperature can be used as a standard to verify radiation thermometers for working purposes. This method is simple and convenient, which is often used in daily work. However, the regulation does not provide an example for the evaluation of uncertainty. This paper presents a method for evaluating the uncertainty of the verification of radiation thermometers for working purposes.
Keywords: reference radiation source; radiation thermometer; trace to the source; uncertainty
1檢定條件和方法
1)環(huán)境條件。(剩余1562字)