礦用溫度傳感器校準方法探究及應(yīng)用
打開文本圖片集
【摘要】本文主要介紹了礦用溫度傳感器相關(guān)計量特性,明確了校準條件,確定了校準項目和校準方法,同時給出相關(guān)測量結(jié)果的不確定度評定示例,為校準礦用溫度傳感器提供了一種可參考的方法。
【關(guān)鍵詞】礦用溫度傳感器;響應(yīng)時間;信號傳輸誤差;校準方法;不確定度評定
【DOI編碼】10.3969/j.issn.1674-4977.2024.05.073
Exploration and Application of Calibration Methods for Mining Temperature Sensors
WANG Hu
(Yulin Institute of Measurement Technology, Yulin 719000, China)
Abstract: The article mainly introduces the relevant metrological characteristics of mining temperature sensors, clarifies the calibration conditions, determines the calibration items and methods, and provides an example of uncertainty evaluation of relevant measurement results, providing a reference method for calibrating mining temperature sensors.
Keywords: mining temperature sensor; response time; signal transmission error; calibration method; uncertainty assessment
礦用溫度傳感器主要用于連續(xù)監(jiān)測并顯示井下作業(yè)環(huán)境、通風(fēng)巷道、密閉硐室內(nèi)的環(huán)境溫度值。(剩余3410字)