空調(diào)系統(tǒng)風平衡調(diào)試技術研究
打開文本圖片集
【摘 要】:針對基準風口法在空調(diào)系統(tǒng)分平衡調(diào)試工作中的局限性,以基準風口法為基礎總結(jié)了一套實用的現(xiàn)場調(diào)試方法“風量調(diào)節(jié)法”,即從超設計風量的風口調(diào)起,依次調(diào)到風量最小的風口,如此循環(huán)反復,直至每個風口都達到設計值;有效地降低了風管系統(tǒng)阻力,提高了調(diào)試工作成功率。
【關鍵詞】:空調(diào)系統(tǒng);風平衡調(diào)試;基準風口法
【中圖分類號】:TU831 【文獻標志碼】:C 【文章編號】:1008-3197(2024)02-59-04
【DOI編碼】:10.3969/j.issn.1008-3197.2024.02.015
Research on Wind Balance Debugging Technology for Air Conditioning Systems
GONG Tairui
(Kunshan Construct Engineering Quality Testing Center,Kunshan 215300,China)
【Abstract】:Aiming at the limitations of the benchmark air outlet method in wind balancedebugging workof air-conditioning system,based on the benchmark air outlet method, the paper has summarized a set of applicable on-site debugging methods called "air volume adjustment method". That is, starting from the air outlet that exceeds the design air volume, adjusting it sequentially to the air outlet with the minimum air volume, and repeating this cycle until each air outlet reaches the design value. It can effectively reduce the resistance of the air duct system and improve the success rate of debugging work.
【Key words】:air-conditioning system;wind balance debugging;reference air outlet method
通風空調(diào)系統(tǒng)施工完畢后、正式運行前,要通過測試對系統(tǒng)各分支管的風量進行調(diào)整[1],使各風口按照設計風量送風,以保證房間的溫濕度和工作區(qū)風速滿足要求。(剩余3332字)