鼓風(fēng)機(jī)繼電器失效分析

  • 打印
  • 收藏
收藏成功


打開文本圖片集

【摘  要】繼電器作為小電流控制大電流的保護(hù)器件,是汽車低壓電路電源分配的重要電器件,用電器功能實(shí)現(xiàn)的重要組成部分,因?yàn)槠涮厥獾慕Y(jié)構(gòu),常常又是故障發(fā)生率高的零件之一。本文針對路試驗(yàn)證中發(fā)生的繼電器失效情況,分析探討故障原因,并提出解決辦法,為后續(xù)繼電器的優(yōu)化和改善提供有力依據(jù)。

【關(guān)鍵詞】繼電器 ;失效 ;依據(jù)

中圖分類號(hào):U463.6    文獻(xiàn)標(biāo)志碼:A    文章編號(hào):1003-8639( 2022 )07-0068-03

Failure Analysis of Blower Relay

HE Yong-li,LI Bei-wen

(SAIC General Wuling Automotive Co.,Ltd.,Liuzhou 545007,China)

【Abstract】Relay,as a protection production for large current,is an important electrical part for low-voltage circuit power distribution in automobiles,and an important part of electrical function realization. Because of its special structure,it is one of the parts with high failure rate. In view of the relay failure in the road test certificate,this paper analyzes and discusses the cause of the failure,and puts forward the solution,which provides a strong basis for the optimization and improvement of the relay.

【Key words】relay;failure;basis

作者簡介 何永利(1987—),女,工程師,主要研究方向?yàn)檎囯娫捶峙浜途€束設(shè)計(jì)。(剩余2592字)