摘  要:某光伏電站發(fā)生一起主變重瓦斯保護(hù)動(dòng)作跳閘事件,通過(guò)故障錄波圖分析、主變檢查和試驗(yàn)等,確定本次事件是一起由于儲(chǔ)油柜金屬波紋管卡澀引起的重瓦斯保護(hù)誤動(dòng)作事件。該文詳細(xì)分析事件處理過(guò)程及事件發(fā)生的根本原因,提出防范措施,避免類(lèi)似事件重復(fù)發(fā)生。

關(guān)鍵詞:變壓器;金屬波紋儲(chǔ)油柜;重瓦斯保護(hù);防范措施;光伏電站

中圖分類(lèi)號(hào):TM411      文獻(xiàn)標(biāo)志碼:A          文章編號(hào):2095-2945(2024)34-0150-04

Abstract: A tripping event occurred in a photovoltaic power station for heavy gas protection of the main transformer. Through fault recorder analysis, main transformer inspection and testing, it was determined that this event was a misoperation of heavy gas protection caused by the stuck metal bellows of the oil conservator. event The incident handling process and the root cause of the incident are analyzed in detail, and preventive measures are proposed to avoid the recurrence of similar incidents.

Keywords: transformer; corrugated metal oil conservator; heavy gas protection; precautionary measures; photovoltaic power station

主變壓器是光伏電站最重要的設(shè)備之一,不僅承擔(dān)著電能轉(zhuǎn)換的核心任務(wù),還是系統(tǒng)安全、穩(wěn)定運(yùn)行的重要保障,一旦發(fā)生故障,可能引起全站失電,甚至影響系統(tǒng)的穩(wěn)定性[1]。(剩余2736字)